• 3-10HP House Heating Cooling Heat Pump with Full Inverter Technology
  • 3-10HP House Heating Cooling Heat Pump with Full Inverter Technology
  • 3-10HP House Heating Cooling Heat Pump with Full Inverter Technology
  • 3-10HP House Heating Cooling Heat Pump with Full Inverter Technology
  • 3-10HP House Heating Cooling Heat Pump with Full Inverter Technology
  • 3-10HP House Heating Cooling Heat Pump with Full Inverter Technology

3-10HP House Heating Cooling Heat Pump with Full Inverter Technology

Certification: RoHS, CB, CCC, ISO9001, CE
Working Medium: R32 or R410A
Heat Source Type: Air Source Heat Pump
Colour: Grey/White
Service: OEM
Control: WiFi/RS485
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • PRODUCTION DESCRIPTION
  • KEY FEATURES
  • KEY COMPONENTS
  • APPLICATION DIAGRAM
  • TECHNICAL SPECIFICATIONS
  • MANUFACTURING & SHIPMENT
  • ADVANTAGES & MARKET OVERVIEW
  • FAQ
Overview

Basic Info.

Model NO.
EDHP-16S (6HP)
Controller
Wired Controller
Heating Capacity
16~18kw
Heat Exchanger
Swep Plate Heat Exchanger
Water Pump
Wilo/Shinhoo DC Water Pump
Electric Heater
3kw or 6kw
Transport Package
Carton+Wooden Pallet for Container Order
Specification
6HP
Trademark
Blueway
Origin
Guangdong, China
HS Code
8418612090
Production Capacity
1000 Sets/Month

Product Description

PRODUCTION DESCRIPTION

 
R32 or R410a DC Inverter Heat Pump (ErP A++, ErP A+++) with EVI compressor technology and full inverter technology for extremely cold area and high outlet water temperature. Equipped with heating, cooling and domestic hot water functions for families, apartments, small industrial sites, etc. Additionally, it can work with solar, boiler or electric heater according to the practical condition of the heating system. With R410a refrigerant, most advance inverter technology & intelligent defrost function to work well in -35ºC, which is much more higher efficiency than normal air source heat pump.
3-10HP House Heating Cooling Heat Pump with Full Inverter Technology
 

KEY FEATURES

 
3-10HP House Heating Cooling Heat Pump with Full Inverter Technology

1) Extended working range down to -35°C ambient (low ambient type)

2) 5 modes: heating only, heating+DHW, cooling only, cooling+DHW, DHW only

3) Low running costs and high efficiency

4) Long-life and corrosion resistant composite cabinet stands up to severe climates

5) Famous compressor ensures outstanding performance and durability

6) LCD touch screen with self-diagnostic control function

7) With control output for three-way valve

8) Easy operation and simple installation

9) WIFI control function is optional

 

KEY COMPONENTS

High Energy Saving & High Power Technology

 

Blueway has its own R&D team & professional test laboratory, which has developed mature control system. Inverter units with accurate temperature control by DC inverter technology, with multi-protection, automatic defrost, WI-FI control function, etc.

3-10HP House Heating Cooling Heat Pump with Full Inverter Technology
3-10HP House Heating Cooling Heat Pump with Full Inverter Technology

Intelligent Control

 

The units are supplied with micro processor based digital controller with LCD touch display. The controller is programmed to provide a maximum protection to the heat pump system and accurate temperature control. The control panel is completely factory wired with all accessories and terminals included.

SWEP Plate Heat Exchanger


High corrosion resistance

High thermal efficiency

High working temperature

3-10HP House Heating Cooling Heat Pump with Full Inverter Technology
 
3-10HP House Heating Cooling Heat Pump with Full Inverter Technology

High Efficiency Compressor

 

High efficienty and energy saving

Quiet operation due to less moving parts

Adopt famous brand rotary or scroll compressor

High Efficiency Class A Pump

 

Energy saving pump with constant volume or pressure adjustment function. German Wilo or Chinese Shinoo water pump is optional.

3-10HP House Heating Cooling Heat Pump with Full Inverter Technology
 

APPLICATION DIAGRAM

Split Type:
3-10HP House Heating Cooling Heat Pump with Full Inverter Technology

3-10HP House Heating Cooling Heat Pump with Full Inverter Technology

Monoblock Type:
3-10HP House Heating Cooling Heat Pump with Full Inverter Technology
 

TECHNICAL SPECIFICATIONS

Options: EVI Low Ambient & Normal Ambient Type (Split & Monoblock Type)

DC Inverter Heat Pump (Split Type)
Model EDHP-09S EDHP-14S EDHP-16S EDHP-24S EDHP-30S
HP 3 5 6 8 10
Power supply Indoor unit V/Hz/Ph 220-240/50/1, 380-415/50/3
Outdoor unit V/Hz/Ph 220-240/50/1   380-415/50/3
+7°C/35°C
Floor heating 
Heating capacity kW/h 9 14  16  24  30
Power input kW 2 3.04 3.5 5.4 7.3
COP - 4.5 4.6 4.56 4.45 4.1
+2°C/35°C 
Floor heating
Heating capacity kW/h 8.5 12.5 14.3 21.7 28
Power input kW 2.18 3.13 3.7  5.5  7.2
COP - 3.9 4.0  3.92 4.0  3.9
-7°C/35°C
Floor heating
Heating capacity kW/h 7.1 11 13 18.9 24
Power input kW 2.4 3.61 4.4 6.52 8
COP - 2.96 3.05 2.95 2.9 3
+7°C/45°C
Radiators
Heating capacity kW/h 8.5 13 15 20.6 29
Power input kW 2.4 3.6 4.41 5.9 8.5
COP - 3.54 3.62 3.4 3.5 3.4
 -7°C/45°C
Radiators
Heating capacity kW/h 6.8 10.2 12.5 18.0  22
Power input kW 2.9 4.23 5.2 7.6 9.6
COP - 2.34 2.41 2.4 2.37 2.3
+7°C/55°C
Hot water
Heating capacity kW/h 6 12 14 20 24
Power input kW 2.26 4 4.91 7.1 9.2
COP - 2.65 3 2.85 2.8 2.6
 -12°C/41°C
Floor heating
Heating capacity kW/h 6 10.5 11.5 17.8  22
Power input kW 2.6 4.5 5.1 7.74 9.6
COP - 2.3 2.36 2.26 2.3 2.3
+35°C/7°C
Fan coil
Cooling capacity kW/h 7 11 13 20 24
Power input kW 2.6 3.95 4.81 7.25 9.2
EER - 2.7 2.8 2.7 2.76 2.6
Energy efficiency class Floor heating - A++ A++ A++ A++ A+
DHW mode - A+ A+ A+ A+ A+
Heating operation range Ambient °C -25~25
Water side °C 18~60
Cooling operation range Ambient °C 10~43
Water side °C 7~22
Domestic hot water operation range Ambient °C -25~35
Water side °C 25~60
Rated water flow rate m³/h 1.5  2.4  2.8  4.1  5.2 
Rated pressure drop kPa 30 45 45 40 47
Max. working pressure Refrigerant Bar 44 44 44 44 44
Water Bar 7 7 7 7 7
Controller - Micro processor based digital wire controller with LCD display
External cabinet - Galvanized steel with powder coating
Compressor Type - Rotary Rotary/Scroll
Qty. Nos. 1 1 1 1 1
Refrigerant - R32/R410a  
Water heat exchanger - SUS 316 Brazed plate heat exchanger
Electric heater kW 3/6 6
Water pump - DC type, Wilo/Shinhoo Shinhoo
Expansion tank L 5 8 10
Water connection Inlet&Outlet inch 1" 1" 1" 1" 1-1/4"
Noise level Indoor Unit dB(A) 42 42 42 42 42
Outdoor Unit dB(A) 52 56 58 59 61
Net dimension (W*D*H) Indoor Unit mm 522*296*863.5 522*296*863.5 522*296*863.5 522*296*863.5 602*308*880
Outdoor Unit mm 950*445*800 976*410*1273 940*448*1365 1150*480*1565 1405*590*1626
Net weight Indoor Unit kg 55 55 55 55 70
Outdoor Unit kg 58 90 100 120 175
Rough loading 20GP/40GP/40HQ set 24/48/48 23/48/52 23/48/52 19/41/41 12/27/27
Notes:
1.The values of heating(cooling) capacity/power input/COP(EER) are based on measurement of EN14511 standard.Usage environment, such as operation of the heat pump, room temperature and controller adjustments, may cause disparities between practically determined and these values;                                                            
2.Sound pressure level measured at distance of 1m from the device;                                                                                                                                                                                     
3.For wall-mounted type, the compressor is located in the outdoor unit;
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
DC Inverter Heat Pump (Monoblock Type)
Model EDHP-09M EDHP-14M EDHP-16M EDHP-24M EDHP-30M
HP 3 5 6 8 10
Power supply V/Hz/Ph 220-240/50/1   380-415/50/3
+7°C/35°C
Floor heating 
Heating capacity kW/h 9 14  16  24  30
Power input kW 2 3.04 3.5 5.4 7.3
COP - 4.5 4.6 4.56 4.45 4.1
+2°C/35°C 
Floor heating
Heating capacity kW/h 8.5 12.5 14.3 21.7 28
Power input kW 2.18 3.13 3.7  5.5  7.2
COP - 3.9 4.0  3.92 4.0  3.9
-7°C/35°C
Floor heating
Heating capacity kW/h 7.1 11 13 18.9 24
Power input kW 2.4 3.61 4.4 6.52 8
COP - 2.96 3.05 2.95 2.9 3
+7°C/45°C
Radiators
Heating capacity kW/h 8.5 13 15 20.6 29
Power input kW 2.4 3.6 4.41 5.9 8.5
COP - 3.54 3.62 3.4 3.5 3.4
 -7°C/45°C
Radiators
Heating capacity kW/h 6.8 10.2 12.5 18.0  22
Power input kW 2.9 4.23 5.2 7.6 9.6
COP - 2.34 2.41 2.4 2.37 2.3
+7°C/55°C
Hot water
Heating capacity kW/h 6 12 14 20 24
Power input kW 2.26 4 4.91 7.1 9.2
COP - 2.65 3 2.85 2.8 2.6
 -12°C/41°C
Floor heating
Heating capacity kW/h 6 10.5 11.5 17.8  22
Power input kW 2.6 4.5 5.1 7.74 9.6
COP - 2.3 2.36 2.26 2.3 2.3
+35°C/7°C
Fan coil
Cooling capacity kW/h 7 11 13 20 24
Power input kW 2.6 3.95 4.81 7.25 9.2
EER - 2.7 2.8 2.7 2.76 2.6
Energy efficiency class Floor heating - A++ A++ A++ A++ A+
DHW mode - A+ A+ A+ A+ A+
Heating operation range Ambient °C -25~25
Water side °C 18~60
Cooling operation range Ambient °C 10~43
Water side °C 7~22
Domestic hot water operation range Ambient °C -25~35
Water side °C 25~60
Rated water flow rate m³/h 1.5  2.4  2.8  4.1  5.2 
Rated pressure drop kPa 30 45 45 40 47
Max. working pressure Refrigerant Bar 44 44 44 44 44
Water Bar 7 7 7 7 7
Controller - Micro processor based digital wire controller with LCD display
External cabinet - Galvanized steel with powder coating
Compressor Type - Rotary Rotary/Scroll
Qty. Nos. 1 1 1 1 1
Refrigerant - R32/R410a
Water heat exchanger - SUS 316 Brazed plate heat exchanger
Electric heater (optional) kW 3/6 6
Water pump (optional) - DC type, Wilo/Shinhoo Shinhoo
Expansion tank (optional) L 5 8 10
Water connection Inlet&Outlet inch 1" 1" 1" 1" 1-1/4"
Noise level dB(A) 52 56 58 59 61
Net dimension (W*D*H) mm 1160*430*820 1079*430*1273 1079*430*1368 1150*480*1565 1405*590*1626
kg 75 130 145 157 230
Rough loading 20GP/40GP/40HQ set 42/92/92 26/54/54 26/54/54 19/41/41 12/27/27
Notes:
1.The values of heating(cooling) capacity/power input/COP(EER) are based on measurement of EN14511 standard.Usage environment, such as operation of the heat pump, room temperature and controller adjustments, may cause disparities between practically determined and these values;                                                      
2.Sound pressure level measured at distance of 1m from the device;                                                                                                                         
3.If local ambient temperature will be below 0°C in winter, please use an approved antifreeze solution;
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 

MANUFACTURING & SHIPMENT

 

3-10HP House Heating Cooling Heat Pump with Full Inverter Technology

 

ADVANTAGES & MARKET OVERVIEW

 

1.Blueway has around 30 years of rich HVAC manufacturing experience.

2.Over 1000 original R&D products, Blueway is qualified to be OEM/OBM/ODM.

3.Over 10000 engineering solutions with great success provided by Blueway.

4.Online technical service is available twenty-four hours a day without break.

5.Blueway intelligent control system with precise timing, temperature control & remote monitoring function.
 

With advanced technology and R&D capacity, Blueway has obtained over more than 20 patents and become one of the leading HVAC manufacturers in China. Meanwhile, 70% of Blueway products have been exported to oversea markets, including Australia, Europe, North America, Middle East, South Africa, South America and obtained worldwide recognition. Additionally, it has over 20 representative offices located in different cities of China, and also has its authorized distributors in Europe, Middle East, North America and South America.

 

So far, Blueway has already provided over 10000 engineering solutions with great success. What's more, Blueway is also the recommended brand by Hilton Hotel in Chinese market. Blueway will continue its endeavor and commitment to serve its worldwide partners by providing solutions and innovative products of high efficiency.
 

3-10HP House Heating Cooling Heat Pump with Full Inverter Technology

 

FAQ

Q: Which one is the hot selling model?

A: EDHP-16S is the hot sale model in European market, it can reach to 18kW heating capacity.

 

Q: What's the selling point of this product series?

A: This product series adopt Mitsubishi or Panasonic inverter rotary compressor, DC fan motor, DC watet pump for 3-8HP models, and can easily control the unit via mobile app after WIFI connection. And some models have already gotten ErP A++ labels from TUV certificate company.

 

Q: How about the refrigerant type?

A: For monoblock type, R32/R410a are optional. For split type, R32 & R410a are optional for EDHP-09 (3HP). But for EDHP-12/14/16/24/30 (4-10HP) only have R410a.

 

Q: How about the compressor?

A: Generally, we adopt Mitsubish or Panasonic inverter rotary compressor.

 

Q: What's the MOQ?

A: Generally, one unit of sample order is acceptable, but quotation will be a little higher than container order.

 

Q: How long is the warranty time?

A: Generally, one year for the whole unit, three years for the compressor.

 

Q: How about the after-sales service?

A: Generally, we only provide online technical support. So far, we have authorized distributors & repair centers in Europe, Middle East, North America & South America for the oversea markets.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001, ISO 14001
OEM/ODM Availability
Yes