Customization: | Available |
---|---|
After-sales Service: | Online Technical Support |
Warranty: | 1 Year for The Whole Unit, 3 Years for Compressor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Super sim body(height 200mm), Minimum depth only 450mm, smaller than other suppliers, saving much installation space.
Cassette with built-in drain pump, can lift water up to 750mm, convinient for installation and improving drainage efficiency.
Indoor units run stable and reliable with high efficiency fan motor, and noise down to 23dB.
Double air guide panel design, remote control receiving head hidden under the panel, function area delicate digital display, and interior decoration integration, enjoy comfor-table, highlight taste.
Wide ESP Range
The Maximum air supply ESP up to 30Pa can connect longer duct tube. supply strong cooling or heating wind and fasten air cycle.
Standard built air return box, easy to adjust the back air return or down air return based installation requirment.
Options: R410a Split Duct Air Conditioner (Inverter & On-Off, Normal & Low Ambient Type)
Specifications of Inverter Universal Outdoor Unit (R410A Cooling & Heating) | |||||||
Outdoor Unit | Model | BLA-18HA/DVO | BLA-24HA/DVO | BLA-36HA/DVO | BLA-48HA/DVO | BLA-60HA/DV3O | |
Capacity | Cooling Capacity | Btu/h | 18000 | 24000 | 36000 | 48000 | 55000 |
kW | 5.300 | 7.050 | 10.550 | 14.000 | 16.000 | ||
Heating Capacity | Btu/h | 19800 | 26400 | 39600 | 52800 | 60500 | |
kW | 5.800 | 7.750 | 11.600 | 15.500 | 17.600 | ||
Electrical Parts | Power Supply | V/Hz/Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 380-415V~/50Hz/3Ph | 380-415V~/50Hz/3Ph |
Air Flow Volume | m³/h | 2600 | 3500 | 4900 | 6300 | 6300 | |
Noise Level | dB(A) | 55 | 58 | 59 | 60 | 60 | |
Outdoor Dimension | Unit(W×H×D) | mm | 780×605×290 | 930×700×330 | 1015×810×445 | 940×1360×440 | 940×1360×440 |
Packing(W×H×D) | mm | 863×653×412 | 980×760×380 | 1065×865×485 | 1030×1480×450 | 1030×1480×450 | |
Outdoor Weight | Net | kg | 33 | 52 | 72 | 98 | 108 |
Gross | kg | 36 | 57 | 77 | 108 | 117 | |
Piping Size | Liquid Pipe Size | mm | φ6.35 | φ9.52 | φ9.52 | φ9.52 | φ9.52 |
Gas Pipe Size | mm | φ12.7 | φ15.88 | φ15.88 | φ15.88 | φ15.88 | |
Max.Pipe Length | m | 35 | 35 | 50 | 50 | 50 | |
Max.Height Difference | m | 25 | 25 | 30 | 30 | 30 | |
Operating Range | Cooling | ºC | 21~43 | 21~43 | 21~43 | 21~43 | 21~43 |
Heating | ºC | -7~24 | -7~24 | -7~24 | -7~24 | -7~24 | |
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
Specifications of Inverter Duct Air Conditioner (R410A Cooling & Heating) | |||||||
Indoor Unit | Model | BLA-18D2HRA/DVI | BLA-24D2HRA/DVI | BLA-36D2HRA/DVI | BLA-48D2HRA/DV3I | BLA-60D2HRA/DV3I | |
Capacity | Cooling Capacity | Btu/h | 18000 | 24000 | 36000 | 48000 | 55000 |
kW | 5.300 | 7.050 | 10.550 | 14.000 | 16.000 | ||
Heating Capacity | Btu/h | 20000 | 26500 | 40000 | 50000 | 60500 | |
kW | 5.80 | 7.90 | 11.70 | 14.650 | 17.731 | ||
Electrical Parts | Power Supply | V/Hz/Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph |
Power Input(W) | Cooling | 1635 | 2180 | 3050 | 4180 | 5420 | |
Heating | 1810 | 2350 | 3224 | 4440 | 5460 | ||
Performance | EER | W/W | 3.32 | 3.22 | 3.46 | 3.35 | 3.23 |
COP | W/W | 3.43 | 3.34 | 3.63 | 3.50 | 3.37 | |
Air Flow Volume | m³/h | 1100/900/700 | 1300/1100/900 | 1650/1450/1050 | 2000/1700/1250 | 2200/1800/1600 | |
External Static Pressure | Pa | 40 | 50 | 80 | 100 | 100 | |
Indoor Dimension | Noise Level (dB(A)) | Hi/Med/Low | 43/40/36 | 46/41/37 | 47/44/40 | 49/47/44 | 51/49/46 |
Unit(W×H×D) | mm | 1010×210×470 | 1190×250×640 | 1425×250×640 | 1425×250×640 | 1425×250×640 | |
Indoor Weight | Packing(W×H×D) | mm | 1110×240×510 | 1255×315×720 | 1490×315×720 | 1490×315×720 | 1490×315×720 |
Net | kg | 23 | 26 | 35 | 45 | 45 | |
Gross | kg | 28 | 30 | 40 | 52 | 52 | |
Piping Size | Liquid | mm | φ6.35 | φ9.52 | φ9.52 | φ9.52 | φ9.52 |
Gas | mm | φ12.7 | φ15.88 | φ15.88 | φ15.88 | φ15.88 | |
Drainage | mm | OD25 | OD25 | OD25 | OD25 | OD25 | |
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
Specifications of On/Off Universal Outdoor Unit - Normal Ambient Type (R410A Cooling & Heating) | |||||||
Outdoor Unit | Model | BLC-18HRA/UO | BLC-24HRA/UO | BLC-36HRA/UO | BLC-48HRA/U3O | BLA-60HRA/U3O | |
Capacity | Cooling Capacity | Btu/h | 18000 | 24000 | 36000 | 48000 | 55000 |
kW | 5.300 | 7.050 | 10.550 | 14.000 | 16.000 | ||
Heating Capacity | Btu/h | 20000 | 26500 | 40000 | 50000 | 60500 | |
kW | 5.900 | 7.900 | 12.000 | 14.650 | 17.731 | ||
Electrical Parts | Power Supply | V/Hz/Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 380-415V~/50Hz/3Ph | 380-415V~/50Hz/3Ph | 380-415V~/50Hz/3Ph |
Air Flow Volume | m³/h | 2100 | 3500 | 4900 | 6300 | 6300 | |
Noise Level | dB(A) | 49 | 54 | 58 | 60 | 57 | |
Outdoor Dimension | Unit(W×H×D) | mm | 780×605×290 | 930×700×330 | 1015×810×445 | 940×1360×440 | 940×1360×440 |
Packing(W×H×D) | mm | 863×653×412 | 980×760×380 | 1065×865×485 | 1030×1480×450 | 1030×1480×450 | |
Outdoor Weight | Net | kg | 38 | 51 | 72 | 98 | 108 |
Gross | kg | 42 | 54 | 77 | 108 | 117 | |
Piping Size | Liquid Pipe Size | mm | φ6.35 | φ9.52 | φ9.52 | φ9.52 | φ9.52 |
Gas Pipe Size | mm | φ12.7 | φ15.88 | φ15.88 | φ15.88 | φ15.88 | |
Max.Pipe Length | m | 25 | 30 | 30 | 50 | 50 | |
Max.Height Difference | m | 15 | 15 | 20 | 30 | 30 | |
Operating Range | Cooling | ºC | 21~43 | 21~43 | 21~43 | 21~43 | 21~43 |
Heating | ºC | -7~24 | -7~24 | -7~24 | -7~24 | -7~24 | |
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
Specifications of On/Off Duct Air Conditioner (R410A Cooling & Heating) | |||||||
Indoor Unit | Model | BLC-18D2HRA/UI | BLC-24D2HRA/UI | BLC-36D2HRA/UI | BLC-48D2HRA/UI | BLC-60D2HRA/UI | |
Capacity | Cooling Capacity | Btu/h | 18000 | 24000 | 36000 | 48000 | 55000 |
kW | 5.300 | 7.200 | 10.550 | 14.000 | 16.119 | ||
Heating Capacity | Btu/h | 20000 | 26500 | 40000 | 50000 | 60500 | |
kW | 5.900 | 7.900 | 12.000 | 14.650 | 17.731 | ||
Electrical Parts | Power Supply | V/Hz/Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph |
Power Input(W) | Cooling | 1761 | 2351 | 3584 | 4560 | 5694 | |
Heating | 1513 | 2388 | 3468 | 4446 | 4845 | ||
Performance | EER | W/W | 3.01 | 3.06 | 2.94 | 3.07 | 2.83 |
COP | W/W | 3.90 | 3.31 | 3.46 | 3.30 | 3.66 | |
Air Flow Volume | m³/h | 1170/770/650 | 1400/950/800 | 1800/1500/1350 | 2100/1750/1550 | 2200/1800/1600 | |
External Static Pressure | Pa | 70 | 70 | 80 | 100 | 100 | |
Indoor Dimension | Noise Level (dB(A)) | Hi/Med/Low | 43/35/32 | 46/43/41 | 46/44/42 | 47/44/42 | 47/45/43 |
Unit(W×H×D) | mm | 1010×210×470 | 1190×250×640 | 1425×250×640 | 1425×250×640 | 1425×250×640 | |
Indoor Weight | Packing(W×H×D) | mm | 1110×240×510 | 1255×315×720 | 1490×315×720 | 1490×315×720 | 1490×315×720 |
Net | kg | 23 | 26 | 35 | 45 | 45 | |
Gross | kg | 28 | 30 | 40 | 52 | 52 | |
Piping Size | Liquid | mm | φ6.35 | φ9.52 | φ9.52 | φ9.52 | φ9.52 |
Gas | mm | φ12.7 | φ15.88 | φ15.88 | φ15.88 | φ15.88 | |
Drainage | mm | OD25 | OD25 | OD25 | OD25 | OD25 | |
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
Specifications of On/Off Universal Outdoor Unit - Low Ambient Type (R410A Cooling & Heating) | |||||||
Outdoor Unit | Model | BLC-18CHRA/UO-L | BLC-24HRA/UO-L | BLC-36HA/U3O-L | BLC-48HA/U3O-L | BLC-60HA/U3O-L | |
Capacity | Cooling Capacity | Btu/h | 18000 | 24000 | 36000 | 48000 | 55000 |
kW | 5.300 | 7.050 | 10.550 | 14.000 | 16.000 | ||
Heating Capacity | Btu/h | 20000 | 26500 | 40000 | 50000 | 60500 | |
kW | 5.900 | 7.900 | 12.000 | 14.650 | 17.731 | ||
Electrical Parts | Power Supply | V/Hz/Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 380-415V~/50Hz/3Ph | 380-415V~/50Hz/3Ph | 380-415V~/50Hz/3Ph |
Air Flow Volume | m³/h | 2100 | 3500 | 4900 | 6300 | 6300 | |
Noise Level | dB(A) | 49 | 54 | 58 | 60 | 57 | |
Outdoor Dimension | Unit(W×H×D) | mm | 780×605×290 | 930×700×330 | 1015×810×445 | 940×1360×440 | 940×1360×440 |
Packing(W×H×D) | mm | 863×653×412 | 980×760×380 | 1065×865×485 | 1030×1480×450 | 1030×1480×450 | |
Outdoor Weight | Net | kg | 38 | 51 | 72 | 98 | 108 |
Gross | kg | 42 | 54 | 77 | 108 | 117 | |
Piping Size | Liquid Pipe Size | mm | φ6.35 | φ9.52 | φ9.52 | φ9.52 | φ9.52 |
Gas Pipe Size | mm | φ12.7 | φ15.88 | φ15.88 | φ15.88 | φ15.88 | |
Max.Pipe Length | m | 25 | 30 | 30 | 50 | 50 | |
Max.Height Difference | m | 15 | 15 | 20 | 30 | 30 | |
Operating Range | Cooling | ºC | -15~43 | -15~43 | -15~43 | -15~43 | -15~43 |
Heating | ºC | -7~24 | -7~24 | -7~24 | -7~24 | -7~24 | |
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
Specifications of On/Off Duct Air Conditioner (R410A Cooling & Heating) | |||||||
Indoor Unit | Model | BLC-18D2HRA/UI | BLC-24D2HRA/UI | BLC-36D2HRA/UI | BLC-48D2HRA/U3I | BLC-60D2HRA/U3I | |
Capacity | Cooling Capacity | Btu/h | 18000 | 24000 | 36000 | 48000 | 55000 |
kW | 5.300 | 7.200 | 10.550 | 14.000 | 16.119 | ||
Heating Capacity | Btu/h | 20000 | 26500 | 40000 | 50000 | 60500 | |
kW | 5.900 | 7.900 | 12.000 | 14.650 | 17.731 | ||
Electrical Parts | Power Supply | V/Hz/Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph | 220-240V~/50Hz/1Ph |
Power Input(W) | Cooling | 1761 | 2351 | 3584 | 4560 | 5694 | |
Heating | 1513 | 2388 | 3468 | 4446 | 4845 | ||
Performance | EER | W/W | 3.01 | 3.06 | 2.94 | 3.07 | 2.83 |
COP | W/W | 3.90 | 3.31 | 3.46 | 3.30 | 3.66 | |
Air Flow Volume | m³/h | 1170/770/650 | 1400/950/800 | 1800/1500/1350 | 2100/1750/1550 | 2200/1800/1600 | |
External Static Pressure | Pa | 70 | 70 | 80 | 100 | 100 | |
Indoor Dimension | Noise Level (dB(A)) | Hi/Med/Low | 43/35/32 | 46/43/41 | 46/44/42 | 47/44/42 | 47/45/43 |
Unit(W×H×D) | mm | 1010×210×470 | 1190×250×640 | 1425×250×640 | 1425×250×640 | 1425×250×640 | |
Indoor Weight | Packing(W×H×D) | mm | 1110×240×510 | 1255×315×720 | 1490×315×720 | 1490×315×720 | 1490×315×720 |
Net | kg | 23 | 26 | 35 | 45 | 45 | |
Gross | kg | 28 | 30 | 40 | 52 | 52 | |
Piping Size | Liquid | mm | φ6.35 | φ9.52 | φ9.52 | φ9.52 | φ9.52 |
Gas | mm | φ12.7 | φ15.88 | φ15.88 | φ15.88 | φ15.88 | |
Drainage | mm | OD25 | OD25 | OD25 | OD25 | OD25 | |
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
1.Blueway has around 30 years of rich HVAC manufacturing experience.
2.Over 1000 original R&D products, Blueway is qualified to be OEM/OBM/ODM.
3.Over 10000 engineering solutions with great success provided by Blueway.
4.Online technical service is available twenty-four hours a day without break.
5.Blueway intelligent control system with precise timing, temperature control & remote monitoring function.
With advanced technology and R&D capacity, Blueway has obtained over more than 20 patents and become one of the leading HVAC manufacturers in China. Meanwhile, 70% of Blueway products have been exported to oversea markets, including Australia, Europe, North America, Middle East, South Africa, South America and obtained worldwide recognition. Additionally, it has over 20 representative offices located in different cities of China, and also has its authorized distributors in Europe, Middle East, North America and South America.
So far, Blueway has already provided over 10000 engineering solutions with great success. What's more, Blueway is also the recommended brand by Hilton Hotel in Chinese market. Blueway will continue its endeavor and commitment to serve its worldwide partners by providing solutions and innovative products of high efficiency.
Q: Recommended places of use?
A: Superthin Low ESP Duct type for living room, dining room, bedroom, hotel room, etc. Middle ESP Duct type for shops, lobbies, offices, clubs, etc.
Q: Whether with drain water pump?
A: Yes, cassette with built-in drain pump, which can lift water up, convenient for installation and improving drainage efficiency.
Q: What's the hot selling range?
A: 30K & 48K On-Off and inverter Duct Split Air Conditioning.
Q: Adopt which refrigerant type?
A: R410a.
Q: With remote controller?
A: It depends on the customers, wired or remote controller, WIFI control are for options.
Q: Hong long is the warranty time?
A: 1 year for the whole unit, 3 years for the compressor.
Q: Can be customized?
A: Yes, we can provide customized product based on the actual condition of the engineering site.