• 18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body
  • 18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body
  • 18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body
  • 18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body
  • 18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body
  • 18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body

18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body

After-sales Service: Online Technical Support
Warranty: 1 Year for The Whole Unit, 3 Years for Compressor
Corrosion Durability: General
Noise Level: Ultra Quiet
Mounting: Ceiling Mount
Certification: RoHS, ISO, CE, CCC
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • PRODUCTION DESCRIPTION
  • KEY FEATURES
  • TECHNICAL SPECIFICATIONS
  • MANUFACTURING & SHIPMENT
  • ADVANTAGES & MARKET OVERVIEW
  • FAQ
Overview

Basic Info.

Model NO.
BLA-48D2HRA (48K)
Condition
New
Material
Galvanized Steel Powder Coated
Service
OEM
Controller
Remote Controller
Control
WiFi/RS485
Cooling Capacity
48K
Design
Split
Transport Package
Carton Packing for Container Order
Trademark
Blueway
Origin
Guangdong, China
HS Code
8415102210
Production Capacity
1000 Sets/Month

Product Description

PRODUCTION DESCRIPTION


Duct Air Conditioning systems are designed to perform well in any kind of weather, providing you with convenient comfort throughout all four seasons. With R410a eco-friendly refrigerant, optional on-off and inverter type, customized order is acceptable due to outsatnding R&D capacity from Blueway Company.
 

KEY FEATURES

Super Slim Body


Super sim body(height 200mm), Minimum depth only 450mm, smaller than other suppliers, saving much installation space.

18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body
 
18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body

Built-in drain pump


Cassette with built-in drain pump, can lift water up to 750mm, convinient for installation and improving drainage efficiency.

 

UItra Low Noise


Indoor units run stable and reliable with high efficiency fan motor, and noise down to 23dB.

18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body
 
18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body

High-grade Exquisite Arc Panel (optional)


Double air guide panel design, remote control receiving head hidden under the panel, function area delicate digital display, and interior decoration integration, enjoy comfor-table, highlight taste.

Wide ESP Range

The Maximum air supply ESP up to 30Pa can connect longer duct tube. supply strong cooling or heating wind and fasten air cycle.

 

Personalized Return Air Way


Standard built air return box, easy to adjust the back air return or down air return based installation requirment.

18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body
 

TECHNICAL SPECIFICATIONS

Options: R410a Split Duct Air Conditioner (Inverter & On-Off, Normal & Low Ambient Type)

Specifications of Inverter Universal Outdoor Unit (R410A Cooling & Heating)
Outdoor Unit Model BLA-18HA/DVO BLA-24HA/DVO BLA-36HA/DVO BLA-48HA/DVO BLA-60HA/DV3O
Capacity Cooling Capacity Btu/h 18000 24000 36000 48000 55000
kW 5.300  7.050  10.550  14.000  16.000 
Heating Capacity Btu/h 19800 26400 39600 52800 60500
kW 5.800  7.750  11.600  15.500  17.600 
Electrical Parts Power Supply V/Hz/Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 380-415V~/50Hz/3Ph 380-415V~/50Hz/3Ph
Air Flow Volume m³/h 2600 3500 4900 6300 6300
Noise Level dB(A) 55 58 59 60 60
Outdoor Dimension Unit(W×H×D) mm 780×605×290 930×700×330 1015×810×445 940×1360×440 940×1360×440
Packing(W×H×D) mm 863×653×412 980×760×380 1065×865×485 1030×1480×450 1030×1480×450
Outdoor Weight Net kg 33 52 72 98 108
Gross kg 36 57 77 108 117
Piping Size Liquid Pipe Size mm φ6.35 φ9.52 φ9.52 φ9.52 φ9.52
Gas Pipe Size mm φ12.7 φ15.88 φ15.88 φ15.88 φ15.88
Max.Pipe Length m 35 35 50 50 50
Max.Height Difference m 25 25 30 30 30
Operating Range Cooling ºC 21~43 21~43 21~43 21~43 21~43
Heating ºC -7~24 -7~24 -7~24 -7~24 -7~24
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Specifications of Inverter Duct Air Conditioner (R410A Cooling & Heating)
Indoor Unit Model BLA-18D2HRA/DVI BLA-24D2HRA/DVI BLA-36D2HRA/DVI BLA-48D2HRA/DV3I BLA-60D2HRA/DV3I
Capacity Cooling Capacity Btu/h 18000 24000 36000 48000 55000
kW 5.300  7.050  10.550  14.000  16.000 
Heating Capacity Btu/h 20000 26500 40000 50000 60500
kW 5.80  7.90  11.70  14.650  17.731
Electrical Parts Power Supply V/Hz/Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph
Power Input(W) Cooling 1635 2180 3050 4180 5420
Heating 1810 2350 3224 4440 5460
Performance EER W/W 3.32 3.22 3.46 3.35 3.23
COP W/W 3.43  3.34 3.63 3.50  3.37
Air Flow Volume m³/h 1100/900/700 1300/1100/900 1650/1450/1050 2000/1700/1250 2200/1800/1600
External Static Pressure Pa 40 50 80 100 100
Indoor Dimension Noise Level  (dB(A)) Hi/Med/Low 43/40/36 46/41/37 47/44/40 49/47/44 51/49/46
Unit(W×H×D) mm 1010×210×470 1190×250×640 1425×250×640 1425×250×640 1425×250×640
Indoor Weight Packing(W×H×D) mm 1110×240×510 1255×315×720 1490×315×720 1490×315×720 1490×315×720
Net kg 23 26 35 45 45
Gross kg 28 30 40 52 52
Piping Size Liquid mm φ6.35 φ9.52 φ9.52 φ9.52 φ9.52
Gas mm φ12.7 φ15.88 φ15.88 φ15.88 φ15.88
Drainage mm OD25 OD25 OD25 OD25 OD25
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Specifications of On/Off Universal Outdoor Unit - Normal Ambient Type (R410A Cooling & Heating)
Outdoor Unit Model BLC-18HRA/UO BLC-24HRA/UO BLC-36HRA/UO BLC-48HRA/U3O BLA-60HRA/U3O
Capacity Cooling Capacity Btu/h 18000 24000 36000 48000 55000
kW 5.300  7.050  10.550  14.000  16.000 
Heating Capacity Btu/h 20000 26500 40000 50000 60500
kW 5.900  7.900  12.000  14.650  17.731
Electrical Parts Power Supply V/Hz/Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 380-415V~/50Hz/3Ph 380-415V~/50Hz/3Ph 380-415V~/50Hz/3Ph
Air Flow Volume m³/h 2100 3500 4900 6300 6300
Noise Level dB(A) 49 54 58 60 57
Outdoor Dimension Unit(W×H×D) mm 780×605×290 930×700×330 1015×810×445 940×1360×440 940×1360×440
Packing(W×H×D) mm 863×653×412 980×760×380 1065×865×485 1030×1480×450 1030×1480×450
Outdoor Weight Net kg 38 51 72 98 108
Gross kg 42 54 77 108 117
Piping Size Liquid Pipe Size mm φ6.35 φ9.52 φ9.52 φ9.52 φ9.52
Gas Pipe Size mm φ12.7 φ15.88 φ15.88 φ15.88 φ15.88
Max.Pipe Length m 25 30 30 50 50
Max.Height Difference m 15 15 20 30 30
Operating Range Cooling ºC 21~43 21~43 21~43 21~43 21~43
Heating ºC -7~24 -7~24 -7~24 -7~24 -7~24
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Specifications of On/Off Duct Air Conditioner (R410A Cooling & Heating)
Indoor Unit Model BLC-18D2HRA/UI BLC-24D2HRA/UI BLC-36D2HRA/UI BLC-48D2HRA/UI BLC-60D2HRA/UI
Capacity Cooling Capacity Btu/h 18000 24000 36000 48000 55000
kW 5.300  7.200  10.550  14.000  16.119 
Heating Capacity Btu/h 20000 26500 40000 50000 60500
kW 5.900  7.900  12.000  14.650  17.731
Electrical Parts Power Supply V/Hz/Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph
Power Input(W) Cooling 1761 2351 3584 4560 5694
Heating 1513 2388 3468 4446 4845
Performance EER W/W 3.01 3.06 2.94 3.07 2.83
COP W/W 3.90  3.31 3.46 3.30  3.66
Air Flow Volume m³/h 1170/770/650 1400/950/800 1800/1500/1350 2100/1750/1550 2200/1800/1600
External Static Pressure Pa 70 70 80 100 100
Indoor Dimension Noise Level  (dB(A)) Hi/Med/Low 43/35/32 46/43/41 46/44/42 47/44/42 47/45/43
Unit(W×H×D) mm 1010×210×470 1190×250×640 1425×250×640 1425×250×640 1425×250×640
Indoor Weight Packing(W×H×D) mm 1110×240×510 1255×315×720 1490×315×720 1490×315×720 1490×315×720
Net kg 23 26 35 45 45
Gross kg 28 30 40 52 52
Piping Size Liquid mm φ6.35 φ9.52 φ9.52 φ9.52 φ9.52
Gas mm φ12.7 φ15.88 φ15.88 φ15.88 φ15.88
Drainage mm OD25 OD25 OD25 OD25 OD25
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Specifications of On/Off Universal Outdoor Unit - Low Ambient Type (R410A Cooling & Heating)
Outdoor Unit Model BLC-18CHRA/UO-L BLC-24HRA/UO-L BLC-36HA/U3O-L BLC-48HA/U3O-L BLC-60HA/U3O-L
Capacity Cooling Capacity Btu/h 18000 24000 36000 48000 55000
kW 5.300  7.050  10.550  14.000  16.000 
Heating Capacity Btu/h 20000 26500 40000 50000 60500
kW 5.900  7.900  12.000  14.650  17.731
Electrical Parts Power Supply V/Hz/Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 380-415V~/50Hz/3Ph 380-415V~/50Hz/3Ph 380-415V~/50Hz/3Ph
Air Flow Volume m³/h 2100 3500 4900 6300 6300
Noise Level dB(A) 49 54 58 60 57
Outdoor Dimension Unit(W×H×D) mm 780×605×290 930×700×330 1015×810×445 940×1360×440 940×1360×440
Packing(W×H×D) mm 863×653×412 980×760×380 1065×865×485 1030×1480×450 1030×1480×450
Outdoor Weight Net kg 38 51 72 98 108
Gross kg 42 54 77 108 117
Piping Size Liquid Pipe Size mm φ6.35 φ9.52 φ9.52 φ9.52 φ9.52
Gas Pipe Size mm φ12.7 φ15.88 φ15.88 φ15.88 φ15.88
Max.Pipe Length m 25 30 30 50 50
Max.Height Difference m 15 15 20 30 30
Operating Range Cooling ºC -15~43 -15~43 -15~43 -15~43 -15~43
Heating ºC -7~24 -7~24 -7~24 -7~24 -7~24
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Specifications of On/Off Duct Air Conditioner (R410A Cooling & Heating)
Indoor Unit Model BLC-18D2HRA/UI BLC-24D2HRA/UI BLC-36D2HRA/UI BLC-48D2HRA/U3I BLC-60D2HRA/U3I
Capacity Cooling Capacity Btu/h 18000 24000 36000 48000 55000
kW 5.300  7.200  10.550  14.000  16.119 
Heating Capacity Btu/h 20000 26500 40000 50000 60500
kW 5.900  7.900  12.000  14.650  17.731
Electrical Parts Power Supply V/Hz/Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph 220-240V~/50Hz/1Ph
Power Input(W) Cooling 1761 2351 3584 4560 5694
Heating 1513 2388 3468 4446 4845
Performance EER W/W 3.01 3.06 2.94 3.07 2.83
COP W/W 3.90  3.31 3.46 3.30  3.66
Air Flow Volume m³/h 1170/770/650 1400/950/800 1800/1500/1350 2100/1750/1550 2200/1800/1600
External Static Pressure Pa 70 70 80 100 100
Indoor Dimension Noise Level  (dB(A)) Hi/Med/Low 43/35/32 46/43/41 46/44/42 47/44/42 47/45/43
Unit(W×H×D) mm 1010×210×470 1190×250×640 1425×250×640 1425×250×640 1425×250×640
Indoor Weight Packing(W×H×D) mm 1110×240×510 1255×315×720 1490×315×720 1490×315×720 1490×315×720
Net kg 23 26 35 45 45
Gross kg 28 30 40 52 52
Piping Size Liquid mm φ6.35 φ9.52 φ9.52 φ9.52 φ9.52
Gas mm φ12.7 φ15.88 φ15.88 φ15.88 φ15.88
Drainage mm OD25 OD25 OD25 OD25 OD25
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 

MANUFACTURING & SHIPMENT

 

18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body

 

ADVANTAGES & MARKET OVERVIEW

 

1.Blueway has around 30 years of rich HVAC manufacturing experience.

2.Over 1000 original R&D products, Blueway is qualified to be OEM/OBM/ODM.

3.Over 10000 engineering solutions with great success provided by Blueway.

4.Online technical service is available twenty-four hours a day without break.

5.Blueway intelligent control system with precise timing, temperature control & remote monitoring function.
 

With advanced technology and R&D capacity, Blueway has obtained over more than 20 patents and become one of the leading HVAC manufacturers in China. Meanwhile, 70% of Blueway products have been exported to oversea markets, including Australia, Europe, North America, Middle East, South Africa, South America and obtained worldwide recognition. Additionally, it has over 20 representative offices located in different cities of China, and also has its authorized distributors in Europe, Middle East, North America and South America.

 

So far, Blueway has already provided over 10000 engineering solutions with great success. What's more, Blueway is also the recommended brand by Hilton Hotel in Chinese market. Blueway will continue its endeavor and commitment to serve its worldwide partners by providing solutions and innovative products of high efficiency.
 

18-60K Split Air Conditioning Duct-Ceiling Type with Slim Body

 

FAQ

Q: Recommended places of use?

A: Superthin Low ESP Duct type for living room, dining room, bedroom, hotel room, etc. Middle ESP Duct type for shops, lobbies, offices, clubs, etc.

 

Q: Whether with drain water pump?

A: Yes, cassette with built-in drain pump, which can lift water up, convenient for installation and improving drainage efficiency.

 

Q: What's the hot selling range?

A: 30K & 48K On-Off and inverter Duct Split Air Conditioning.

 

Q: Adopt which refrigerant type?

A: R410a.

 

Q: With remote controller?

A: It depends on the customers, wired or remote controller, WIFI control are for options.

 

Q: Hong long is the warranty time?

A: 1 year for the whole unit, 3 years for the compressor.

 

Q: Can be customized?

A: Yes, we can provide customized product based on the actual condition of the engineering site.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001, ISO 14001
OEM/ODM Availability
Yes