Customization: | Available |
---|---|
Certification: | RoHS, CB, CCC, ISO9001, CE |
Working Medium: | R410A |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Blueway Swimming Pool Water Heater consumes much less electric power than a traditional electric heater. The electric power it consumes is only to operate the compressor, fan and water pump. For every 1kW electricity it consumes, the unit will generate up to 5kW heating capacity, which means 4kW capacity are totally free.
The evaporator or condenser coil used is of fin and tube type. The fins are hydrophilic treated aluminum fins to resist corrosion, and the copper tubes are inner-grooved type, which increases the heat transfer in the refrigerant side.
The units are supplied with micro processor based digital controller with LCD display. The controller is programmed to provide a maximum protection to the heat pump system and accurate temperature control. The control panel is completely factory wired with all accessories and terminals included.
1) High efficiency and super corrosion resistant
2) High working pressure
3) Reliability and long lasting life span
4) Low maintenance
1) With tropical resistance capacity
2) High efficienty and energy saving
3) Quiet operation due to less moving parts
4) Adopt famous brand rotary or scroll compressor
1) For inverter type, R32 & R410a for T1 SPCH series, R410a for T3 SPCH series
2) With heating and cooling function, and WIFI function is optional
3) Rated water outlet temp. range is 26-28ºC
4) Touch screen for higher operating sensitivity and unlimited key operations
5) Saving over 2/3 energy than the conventional equipments
6) Energy-saving, high performance, low noise, easy to operate
Options: On-Off T3 Swimming Pool Chiller & Heat Pump (Domestic & Industrial, 50Hz & 60Hz)
T3 Residential Swimming Pool Chiller & Heat Pump - Top Discharge (On/Off type, 50Hz) | ||||||
Model | T-SPCH3.5V | T-SPCH5V | T-SPCH7V | |||
HP | 3.5 | 5 | 7 | |||
Power Supply | V/Hz/Ph | 220-240/50/1 | 380-415/50/3 | |||
Heating performance | Heating (1): A26°C Humidity 80% W26/28°C |
Heating capacity | kW/h | 14 | 25.5 | 35.7 |
btu/h | 47800 | 87000 | 121800 | |||
Power consumption | kW | 2.45 | 5.31 | 7.44 | ||
COP | w/w | 5.7 | 4.8 | 4.8 | ||
Heating (2): A15°C Humidity 70% W26/28°C |
Heating capacity | kW/h | 10.40 | 19.89 | 27.84 | |
btu/h | 35500 | 67860 | 95004 | |||
Power consumption | kW | 2.36 | 4.71 | 6.59 | ||
COP | w/w | 4.4 | 4.2 | 4.2 | ||
Cooling performance | Cooling (1): A35°C W30/28°C |
Cooling capacity | kW/h | 9.34 | 17.58 | 24.62 |
btu/h | 31866 | 60000 | 84000 | |||
Power consumption | kW | 3.11 | 6.28 | 8.92 | ||
EER | w/w | 2.81 | 2.8 | 2.76 | ||
Cooling (2): A46°C W30/28°C |
Cooling capacity | kW/h | 7.94 | 14.95 | 20.93 | |
btu/h | 27086 | 51000 | 71400 | |||
Power consumption | kW | 4.18 | 7.91 | 10.96 | ||
EER | w/w | 1.9 | 1.89 | 1.91 | ||
Ambient temp. range | °C | -7~53 | ||||
Rated/Max.outlet water temp. | °C | 28/40 | ||||
Rated water flow rate | m³/h | 6 | 11 | 15.3 | ||
Rated pressure drop | kPa | 15 | 16 | 16 | ||
Controller | - | Micro processor based digital wire controller with LCD display | ||||
Fan blade | - | Aluminum | ||||
External cabinet | - | Galvanized steel with powder coating | ||||
Compressor | Type | - | Rotary | |||
Qty. | Nos. | 1 | ||||
Refrigerant | - | R410a | ||||
Water heat exchanger | - | Titanium tube in PVC shell | ||||
Water connection | Inlet&Outlet | inch | 1-1/2'' | 1-1/2'' | 1-1/2'' | |
Sound pressure at 1m | dB(A) | 55 | 55 | 55 | ||
Air discharge | - | Top discharge | ||||
Net dimension | W*D*H | mm | 720*630*750 | 850*745*875 | 850*745*875 | |
Net weight | kg | 72 | 110 | 120 | ||
Notes: 1.Conditions of "Heating (1)": Ambient air temperature: 26°C, Humidity 80%, Inlet/Outlet water temperature: W26/28°C ; 2.Conditions of "Heating (2)": Ambient air temperature: 15°C, Humidity 70%, Inlet/Outlet water temperature: W26/28°C ; 3.Conditions of "Cooling (1)": Ambient air temperature: 35°C, Inlet/Outlet water temperature: W30/28°C ; 4.Conditions of "Cooling (2)": Ambient air temperature: 46°C, Inlet/Outlet water temperature: W30/28°C ; Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
T3 Residential Swimming Pool Chiller & Heat Pump - Top Discharge (On/Off type, 60Hz) | ||||||
Model | T-SPCH3.5Va | T-SPCH5Va | T-SPCH7Va | |||
HP | 3.5 | 5 | 7 | |||
Power Supply | V/Hz/Ph | 208-230/60/1 | 208-230/60/3 | |||
Heating performance | Heating (1): A26°C Humidity 80% W26/28°C |
Heating capacity | kW/h | 14 | 25.5 | 35.7 |
btu/h | 47800 | 87000 | 121800 | |||
Power consumption | kW | 2.45 | 5.31 | 7.44 | ||
COP | w/w | 5.7 | 4.8 | 4.8 | ||
Heating (2): A15°C Humidity 70% W26/28°C |
Heating capacity | kW/h | 10.40 | 19.89 | 27.84 | |
btu/h | 35500 | 67860 | 95004 | |||
Power consumption | kW | 2.36 | 4.71 | 6.59 | ||
COP | w/w | 4.4 | 4.2 | 4.2 | ||
Cooling performance | Cooling (1): A35°C W30/28°C |
Cooling capacity | kW/h | 9.34 | 17.58 | 24.62 |
btu/h | 31866 | 60000 | 84000 | |||
Power consumption | kW | 3.11 | 6.28 | 8.92 | ||
EER | w/w | 2.81 | 2.8 | 2.76 | ||
Cooling (2): A46°C W30/28°C |
Cooling capacity | kW/h | 7.94 | 14.95 | 20.93 | |
btu/h | 27086 | 51000 | 71400 | |||
Power consumption | kW | 4.18 | 7.91 | 10.96 | ||
EER | w/w | 1.9 | 1.89 | 1.91 | ||
Ambient temp. range | °C | -7~53 | ||||
Rated/Max.outlet water temp. | °C | 28/40 | ||||
Rated water flow rate | m³/h | 6 | 11 | 15.3 | ||
Rated pressure drop | kPa | 15 | 16 | 16 | ||
Controller | - | Micro processor based digital wire controller with LCD display | ||||
Fan blade | - | Aluminum | ||||
External cabinet | - | Galvanized steel with powder coating | ||||
Compressor | Type | - | Rotary | |||
Qty. | Nos. | 1 | ||||
Refrigerant | - | R410a | ||||
Water heat exchanger | - | Titanium tube in PVC shell | ||||
Water connection | Inlet&Outlet | inch | 1-1/2'' | 1-1/2'' | 1-1/2'' | |
Sound pressure at 1m | dB(A) | 55 | 55 | 55 | ||
Air discharge | - | Top discharge | ||||
Net dimension | W*D*H | mm | 720*630*750 | 850*745*875 | 850*745*875 | |
Net weight | kg | 72 | 110 | 120 | ||
Notes: 1.Conditions of "Heating (1)": Ambient air temperature: 26°C, Humidity 80%, Inlet/Outlet water temperature: W26/28°C ; 2.Conditions of "Heating (2)": Ambient air temperature: 15°C, Humidity 70%, Inlet/Outlet water temperature: W26/28°C ; 3.Conditions of "Cooling (1)": Ambient air temperature: 35°C, Inlet/Outlet water temperature: W30/28°C ; 4.Conditions of "Cooling (2)": Ambient air temperature: 46°C, Inlet/Outlet water temperature: W30/28°C ; Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
T3 Commercial Swimming Pool Chiller & Heat Pump (On/Off type, 50Hz) | |||||||||||
Model | T-SPCH10 | T-SPCH12 | T-SPCH15 | T-SPCH20 | T-SPCH25 | T-SPCH30 | T-SPCH40 | T-SPCH50 | |||
HP | 10 | 12 | 15 | 20 | 25 | 30 | 40 | 50 | |||
Power Supply | V/Hz/Ph | 380-415/50/3 | |||||||||
Heating performance | Heating (1): A26°C Humidity 80% W26/28°C |
Heating capacity | kW/h | 46 | 55 | 69 | 91 | 114 | 137 | 183 | 229 |
btu/h | 156000 | 187200 | 234000 | 312000 | 390000 | 468000 | 624000 | 780000 | |||
Power consumption | kW | 9.53 | 11.20 | 14.59 | 19.05 | 24.32 | 29.18 | 40.64 | 49.7 | ||
COP | w/w | 4.8 | 4.9 | 4.7 | 4.8 | 4.7 | 4.7 | 4.5 | 4.6 | ||
Heating (2): A15°C Humidity 70% W26/28°C |
Heating capacity | kW/h | 36 | 43 | 53 | 71 | 89 | 107 | 143 | 178 | |
btu/h | 121680 | 146016 | 182520 | 243360 | 304200 | 365040 | 486720 | 608400 | |||
Power consumption | kW | 8.49 | 9.95 | 13.05 | 16.98 | 22.29 | 26.09 | 35.66 | 44.58 | ||
COP | w/w | 4.2 | 4.3 | 4.1 | 4.2 | 4.0 | 4.1 | 4.0 | 4.0 | ||
Cooling performance | Cooling (1): A35°C W30/28°C |
Cooling capacity | kW/h | 35 | 42 | 53 | 70 | 88 | 106 | 141 | 176 |
btu/h | 120000 | 144000 | 180000 | 240000 | 300000 | 360000 | 480000 | 600000 | |||
Power consumption | kW | 13.48 | 16.11 | 20.37 | 26.54 | 33.56 | 40.43 | 53.49 | 67.9 | ||
EER | w/w | 2.61 | 2.62 | 2.59 | 2.65 | 2.62 | 2.61 | 2.63 | 2.59 | ||
Cooling (2): A46°C W30/28°C |
Cooling capacity | kW/h | 30 | 36 | 45 | 60 | 75 | 90 | 120 | 149 | |
btu/h | 102000 | 122400 | 153000 | 204000 | 255000 | 306000 | 408000 | 510000 | |||
Power consumption | kW | 14.87 | 17.08 | 21.87 | 27.94 | 37.75 | 42.10 | 55.88 | 73.63 | ||
EER | w/w | 2.01 | 2.10 | 2.05 | 2.14 | 1.98 | 2.13 | 2.14 | 2.03 | ||
Ambient temp. range | °C | -7~53 | |||||||||
Rated/Max.outlet water temp. | °C | 28/40 | |||||||||
Rated water flow rate | m³/h | 19.7 | 23.6 | 29.5 | 39.3 | 49.1 | 59.0 | 78.6 | 98.3 | ||
Rated pressure drop | kPa | 18 | 18 | 18 | 18 | 25 | 30 | 30 | 30 | ||
Controller | - | Micro processor based digital wire controller with LCD display | |||||||||
Fan blade | - | Aluminum | |||||||||
External cabinet | - | Galvanized steel with powder coating | |||||||||
Compressor | Type | - | Scroll | ||||||||
Qty. | Nos. | 1 or 2 | 2 | 4 | |||||||
Refrigerant | - | R410a | |||||||||
Water heat exchanger | - | Titanium tube in PVC shell | |||||||||
Water connection | Inlet&Outlet | inch | DN50 | DN50 | DN50 | DN50 | DN63 | DN75 | DN110 | DN110 | |
Sound pressure at 1m | dB(A) | 56 | 56 | 56 | 56 | 62 | 62 | 65 | 65 | ||
Air discharge | - | Top discharge | |||||||||
Net dimension | W*D*H | mm | 1480*845*995 | 1480*845*995 | 1480*845*995 | 2000*950*2000 | 2000*950*2100 | 2000*1100*2050 | 2000*1900*2000 | 2000*1900*2100 | |
Net weight | kg | 230 | 230 | 235 | 280 | 290 | 300 | 360 | 380 | ||
Notes: 1.Conditions of "Heating (1)": Ambient air temperature: 26°C, Humidity 80%, Inlet/Outlet water temperature: W26/28°C ; 2.Conditions of "Heating (2)": Ambient air temperature: 15°C, Humidity 70%, Inlet/Outlet water temperature: W26/28°C ; 3.Conditions of "Cooling (1)": Ambient air temperature: 35°C, Inlet/Outlet water temperature: W30/28°C ; 4.Conditions of "Cooling (2)": Ambient air temperature: 46°C, Inlet/Outlet water temperature: W30/28°C ; Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
T3 Commercial Swimming Pool Chiller & Heat Pump (On/Off type, 60Hz) | |||||||||||
Model | T-SPCH10a | T-SPCH12a | T-SPCH15a | T-SPCH20a | T-SPCH25a | T-SPCH30a | T-SPCH40a | T-SPCH50a | |||
HP | 10 | 12 | 15 | 20 | 25 | 30 | 40 | 50 | |||
Power Supply | V/Hz/Ph | 208-230/60/3 | |||||||||
Heating performance | Heating (1): A26°C Humidity 80% W26/28°C |
Heating capacity | kW/h | 46 | 55 | 69 | 91 | 114 | 137 | 183 | 229 |
btu/h | 156000 | 187200 | 234000 | 312000 | 390000 | 468000 | 624000 | 780000 | |||
Power consumption | kW | 9.33 | 11.43 | 14.59 | 19.05 | 24.85 | 29.18 | 40.64 | 50.8 | ||
COP | w/w | 4.9 | 4.8 | 4.7 | 4.8 | 4.6 | 4.7 | 4.5 | 4.5 | ||
Heating (2): A15°C Humidity 70% W26/28°C |
Heating capacity | kW/h | 36 | 43 | 53 | 71 | 89 | 107 | 143 | 178 | |
btu/h | 121680 | 146016 | 182520 | 243360 | 304200 | 365040 | 486720 | 608400 | |||
Power consumption | kW | 8.27 | 10.13 | 12.93 | 16.89 | 22.03 | 25.87 | 36.02 | 45.03 | ||
COP | w/w | 4.3 | 4.2 | 4.1 | 4.2 | 4.0 | 4.1 | 4.0 | 4.0 | ||
Cooling performance | Cooling (1): A35°C W30/28°C |
Cooling capacity | kW/h | 35 | 42 | 53 | 70 | 88 | 106 | 141 | 176 |
btu/h | 120000 | 144000 | 180000 | 240000 | 300000 | 360000 | 480000 | 600000 | |||
Power consumption | kW | 13.48 | 16.11 | 20.37 | 26.54 | 33.56 | 40.43 | 53.49 | 67.9 | ||
EER | w/w | 2.61 | 2.62 | 2.59 | 2.65 | 2.62 | 2.61 | 2.63 | 2.59 | ||
Cooling (2): A46°C W30/28°C |
Cooling capacity | kW/h | 30 | 36 | 45 | 60 | 75 | 90 | 120 | 149 | |
btu/h | 102000 | 122400 | 153000 | 204000 | 255000 | 306000 | 408000 | 510000 | |||
Power consumption | kW | 14.87 | 17.08 | 21.87 | 27.94 | 37.75 | 42.10 | 55.88 | 73.63 | ||
EER | w/w | 2.01 | 2.10 | 2.05 | 2.14 | 1.98 | 2.13 | 2.14 | 2.03 | ||
Ambient temp. range | °C | -7~53 | |||||||||
Rated/Max.outlet water temp. | °C | 28/40 | |||||||||
Rated water flow rate | m³/h | 19.7 | 23.6 | 29.5 | 39.3 | 49.1 | 59.0 | 78.6 | 98.3 | ||
Rated pressure drop | kPa | 18 | 18 | 18 | 18 | 25 | 30 | 30 | 30 | ||
Controller | - | Micro processor based digital wire controller with LCD display | |||||||||
Fan blade | - | Aluminum | |||||||||
External cabinet | - | Galvanized steel with powder coating | |||||||||
Compressor | Type | - | Scroll | ||||||||
Qty. | Nos. | 1 or 2 | 2 | 4 | |||||||
Refrigerant | - | R410a | |||||||||
Water heat exchanger | - | Titanium tube in PVC shell | |||||||||
Water connection | Inlet&Outlet | inch | DN50 | DN50 | DN50 | DN50 | DN63 | DN75 | DN110 | DN110 | |
Sound pressure at 1m | dB(A) | 56 | 56 | 56 | 56 | 62 | 62 | 65 | 65 | ||
Air discharge | - | Top discharge | |||||||||
Net dimension | W*D*H | mm | 1480*845*995 | 1480*845*995 | 1480*845*995 | 2000*950*2000 | 2000*950*2100 | 2000*1100*2050 | 2000*1900*2000 | 2000*1900*2100 | |
Net weight | kg | 230 | 230 | 235 | 280 | 290 | 300 | 360 | 380 | ||
Notes: 1.Conditions of "Heating (1)": Ambient air temperature: 26°C, Humidity 80%, Inlet/Outlet water temperature: W26/28°C ; 2.Conditions of "Heating (2)": Ambient air temperature: 15°C, Humidity 70%, Inlet/Outlet water temperature: W26/28°C ; 3.Conditions of "Cooling (1)": Ambient air temperature: 35°C, Inlet/Outlet water temperature: W30/28°C ; 4.Conditions of "Cooling (2)": Ambient air temperature: 46°C, Inlet/Outlet water temperature: W30/28°C ; Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
1.Blueway has around 30 years of rich HVAC manufacturing experience.
2.Over 1000 original R&D products, Blueway is qualified to be OEM/OBM/ODM.
3.Over 10000 engineering solutions with great success provided by Blueway.
4.Online technical service is available twenty-four hours a day without break.
5.Blueway intelligent control system with precise timing, temperature control & remote monitoring function.
With advanced technology and R&D capacity, Blueway has obtained over more than 20 patents and become one of the leading HVAC manufacturers in China. Meanwhile, 70% of Blueway products have been exported to oversea markets, including Australia, Europe, North America, Middle East, South Africa, South America and obtained worldwide recognition. Additionally, it has over 20 representative offices located in different cities of China, and also has its authorized distributors in Europe, Middle East, North America and South America.
So far, Blueway has already provided over 10000 engineering solutions with great success. What's more, Blueway is also the recommended brand by Hilton Hotel in Chinese market. Blueway will continue its endeavor and commitment to serve its worldwide partners by providing solutions and innovative products of high efficiency.
Q: Colour option?
A: Generally, white or grey for fast production.
Q: Packing?
A: Export plywood pallet.
Q: Refrigerant type?
A: It is recommended to adopt R410a for harsh weather in gulf countries at middle east.
Q: How to choose the right model?
A: Please contact us for further communication..
Q: With WIFI option?
A: Yes, cost is just a little higher.
Q: Which gulf countries do you mainly export?
A: Currently, we mainly export to Kuwait, UAE and Qatar.
Q: Compressor brand?
A: Generally, GMCC or Panasonic for small unit. Bitzer or Copeland or Panasonic for commercial unit.